L1-10D.17 – Cancel Window

L1-10D.17 – Cancel Window A period of time shall be provided, starting at the end of the Abort Window, during which a user can Cancel the alarm The minimum duration of the window shall be five (5) minutes The Cancel Window shall apply to all alarms that have been...

L1-10D.16 – All Burg Zones… “Abort Window”

L1-10D.16 – All Burg Zones… “Abort Window” Burglary – default 30 sec* (15-45 range) Fire – default No delay Hold-up/Tamper – No delay *May disable by zone or zone type! LOCAL ALARM STILL SOUNDS – ONLY COMMUNICATION IS DELAYED...

L1-10D.15 – Abort Window

L1-10D.15 – Abort Window A period of time that allows the user additional time to disarm the system before an alarm is transmitted Too little time prevents the user from disarming the system after false alarms All panels should be set to at least the default of 30...

L1-10D.14 – Universal Disarming Sequence

L1-10D.14 – Universal Disarming Sequence Can disarm any panel by entering the code Makes it easy to teach the user –its confusing if some panels want you to hit a button first and enter the code others want the code first and then the button,...

L1-10D.13 – Entry Delay Prewarn

L1-10D.13 – Entry Delay Prewarn Pre-Warning is Silenced after the 1st digit of the code is entered Allows user to focus on completing the...